Flueline Heating Wood heaters & flues · Maida Vale

Wood heaters & flues · Maida Vale

Wood heater and flue installation, Perth and the hills Freestanding and inbuilt slow-combustion heaters supplied and installed — flued to AS/NZS 2918, smoke-tested on the day, swept every winter.

$5,390

5.0 M FLUE · 600 OVER RIDGE

A freestanding heater under a 2.7 m ceiling, 22.5° tile roof, 2 m out from the ridge — supplied, installed, flued and flashed.

Flued to AS/NZS 2918 Heaters to AS/NZS 4013 Installing since 2008

The Clearance

Build the section —
the standard sets the metres
Section through the house showing the heater, the flue and the AS/NZS 2918 clearanceA drawn section: heater on its hearth, flue rising through the ceiling and roof, and the required cowl height dimensioned above the highest roof within three metres.

$5,390

5.0 M FLUE · 600 OVER RIDGE

    What we’re putting in
    The roof it goes through
    Ceiling and where the flue comes through
    Ceiling height
    2.7metres
    Out from the ridge
    2.0metres
    What it stands on
    Where the house is

    The estimate, line by line

    What we will not pretend

    The same section, in words

      What we get called for

      Eight jobs, and what each one starts at

      Every figure below is GST included and is what the job actually starts at — the shortest flue on our grid, the cheapest flashing, no new hearth. The flue metres are the part that moves, and they are set by the standard, not by us.

      Freestanding heater, supplied & installed

      A slow-combustion heater out of the showroom, carried in, set on its clearances, flued, flashed and smoke-tested before we leave. The one most Perth hills houses end up with.

      from $5,111

      Inbuilt / insert, supplied & installed

      An insert set into an existing masonry opening or a new stud enclosure, with the surround made good and the flue run inside the chase. Neater in a small room, and it keeps the floor.

      from $5,891

      Install only — your heater

      You bought it, or it has been in the shed since the last cold snap. We check it is an AS/NZS 4013 heater, flue it, flash it and leave the compliance plate on the casing.

      from $2,911

      Flue replacement & re-flue

      The heater is fine, the flue has rusted through at the flashing or the cowl has blown off. New twin-wall casing, new flashing, old flue to the tip — the heater and the hearth stay where they are.

      from $2,611

      Flue kit and flue metres

      Twin-wall casing, cowl, ceiling plate, roof plate and heat shield as one kit, then the metres the standard asks for. Billed in half metres, rounded up — never in guessed lengths.

      $640 kit, then $186 a metre

      Roof flashing

      A flashing cut and dressed to the roof you actually have. Tile takes a lead-dressed tray, Colorbond takes a boot to the rib profile — a steeper pitch is a bigger, slower flashing.

      $280–$420 by roof and pitch

      Hearths

      A hearth pad where there is timber floor under the heater, or stone cut to the heater’s own footprint where the room deserves it. Both sized off the manufacturer’s plate, not off a rule of thumb.

      pad $420 · stone from $860

      Flue sweep & service

      Casing swept, cowl and flashing checked, door rope and glass gasket replaced if they are gone. Book it in March and April — by May we are installing, not sweeping.

      $220 · booked separately

      Permits. Some local governments want a building permit for a solid-fuel heater. We’ll tell you whether yours does — it’s your permit, and it isn’t ours to charge you for.

      Who turns up

      Two of us, one ute, and a compliance plate left behind

      Since 2008Eighteen winters of Perth hills installs, out of a Maida Vale workshop.
      Lic. SF0000 · ABN 00 000 000 389Gas & solid-fuel installer licence and ABN, both placeholder-patterned for this demonstration.
      AS/NZS 2918 & AS/NZS 4013Flues installed to 2918; we only install heaters compliant to 4013.
      $20M public liabilityCertificate of currency goes out with the quote, before anyone is on your roof.
      Smoke-tested on the dayWe light it, we watch the draw, and we don’t leave until it pulls.
      We sweep what we installEvery heater we put in goes on the autumn sweep list. You get a text, not an invoice surprise.

      What people said afterwards

      Three jobs, three winters

      Demonstration copy for a fictional business — written the way a real review reads, not marked up as review data.

      ★★★★★

      “The heater sat in our shed for a year because every quote came back as ‘depends on the flue’. Flueline drew the section, showed us why it needed five metres and not three, and the number never moved. In and drawing by four o’clock.”

      Kalamunda · freestanding, tile roof

      ★★★★★

      “Ours had rusted right through where the flue met the flashing — we found it because the ceiling stained. They re-flued it in a morning, took the old one away, and didn’t try to sell us a new heater we didn’t need.”

      Mundaring · re-flue and new flashing

      ★★★★★

      “Raked ceiling, three-six at the ridge, and two other installers had told us it couldn’t be done neatly. It could. They scaffolded inside, ran it dead plumb, and the plate on the casing has the length on it.”

      Bickley · new build, raked ceiling

      Where we work

      The hills are most of our winter

      Out of Maida Vale, at the foot of the scarp. The hills aren’t a travel zone for us — Kalamunda, Mundaring and Roleystone cost exactly what Bayswater costs.

      Flueline Heating service areaA drawn map of the Perth metropolitan area and the Darling Scarp with Maida Vale marked and the suburbs served named.

      Everything inside the metro and everything up the scarp is a normal day for us. Once a year, through autumn, we run a week down south — that’s the only travel we ever quote.

      • Maida Vale
      • Kalamunda
      • Mundaring
      • Roleystone
      • Bickley
      • Midland
      • Bayswater
      • Perth CBD
      • Armadale
      • Gooseberry Hill
      • Lesmurdie
      • Glen Forrest

      Bridgetown, Manjimup and Albany in the autumn runs — we go down for a week at a time and fit jobs into it.

      Asked every March

      Six questions we get before every winter

      Why does my flue have to be that long?

      Because AS/NZS 2918 says so, and the number falls out of your roof, not out of our quote. The cowl has to finish at least 600 mm above the point where the flue comes through, and at least 600 mm above any part of the roof within 3 m horizontally. On a normal gable that second rule is the one that bites.

      Here is the part people find surprising: if the flue comes through inside 3 m of the ridge, the ridge itself is the highest roof in the span — so the cowl has to clear the ridge by 600, and the flue length stops depending on the pitch altogether. Move the flue further down the roof than 3 m and the flue gets shorter, because the highest thing it has to clear is no longer the ridge. The section at the top of this page draws both cases.

      Do I need a council permit?

      Sometimes. Some local governments treat a solid-fuel heater as building work and want a permit; others don’t. We’ll tell you which one yours is when we quote, and we’ll give you what you need to lodge it — but it’s your permit in your name, and it isn’t ours to charge you for.

      How often should the flue be swept?

      Once a year for a heater that runs all winter, and we’d rather do it in March or April than in June. If you burn wet wood, or you damp it right down overnight, make it twice — creosote is what turns a flue fire from a story into an insurance claim. Sweep and service is $220 and it is booked separately from an install.

      Freestanding or inbuilt?

      Freestanding radiates from five sides and heats a big open room better; inbuilt gives you the floor back and looks calmer in a smaller room. Freestanding is cheaper to install because the flue run is simple and everything is reachable. Inbuilt costs more because the enclosure, the chase and the making-good are part of the job.

      There’s an existing masonry chimney — can we use it?

      Often yes, with a stainless liner run the full height and the top made good. But that is a job we price on the roof, not on this form — we need to see the flue’s condition, the throat, and whether the chimney is even plumb. Same goes for an asbestos ceiling or a second-storey penetration.

      When should I book for winter?

      February and March. By the first cold week in May we are three weeks out, and by June we are only doing breakdowns and re-flues. A heater booked in autumn gets installed on a dry roof by two people who aren’t rushing.

      Get a price

      Send us the section you just built

      Fill this in and the job box arrives already carrying what you configured above — heater, roof, ceiling, ridge distance, hearth and zone.

      We’d call you back within one business day, with the flue metres and the flashing already priced.

      If the photos show something the form can’t — a raked ceiling, a second storey, a chimney worth lining — we’ll say so on that call rather than after we’ve arrived.

      Flueline Heating
      Maida Vale WA 6057
      Monday to Friday, 6:30am–4:00pm
      (08) 9000 0389

      Built by Sapience Analytics

      This is a demonstration build by Sapience Analytics.

      Want one pointed at your customers? We build conversion-first sites for WA trades — every pixel drawn in code, the pricing honest, and the enquiry path as short as a phone call.